TROUBLESHOOTING CHART

SYMPTOM

CAUSE

REMEDY

4. Constant exhaust of air at the

air dryer purge valve exhaust

or unable to build system

pressure. (Charge mode.)

A. Air dryer purge valve leaking

excessively.

A. With the compressor loaded, apply a soap solution on the

purge valve exhaust, to test for excessive leakage. Repair

or replace the purge valve as necessary.

Refer to Technical Bulletin TCH-008-040.

B. Purge valve frozen open - faulty heater

and thermostat, wiring, blown fuse.

B. Refer to paragraph 5 of the Operation and Leakage Tests for

the heater and thermostat test.

C. Defective AD-IS air dryer delivery

check valve.

C. Refer to Symptom 1, Remedy B.

D. Leaking Turbo Cut-Off valve.

D. Repair or replace the purge valve assembly.

E. Defective governor.

E. Check the governor at both “cut-in” and “cut-out” positions

for (i) proper pressures and (ii) excessive leakage at fittings

and exhaust.

F. Leaking purge valve control piston

seals.

F. Repair or replace the purge valve assembly.

5. Cannot build system air

pressure.

A. Supply pressure to the air dryer is not

sufficient.

A. Ensure the supply pressure to the air dryer is greater than

110 psi after the system charges.

B. Kinked or blocked (plugged) discharge

line.

B. Check to determine if air passes through discharge line.

Check for kinks, bends, excessive carbon deposits, or ice

blockage.

C. Excessive bends in discharge line

(water collects and freezes).

C. Discharge line should be constantly sloping from compressor

to air dryer with as few bends as possible.

D. Pressure protection valve(s) in air

dryer will not open.

D. Replace air dryer (pressure protection valves are not

serviceable).

E. Refer to Symptom 4.

E. Refer to Symptom 4, Remedy A.

F. Refer to Symptom 7.

F. Refer to Symptom 7, Remedies A and B.

6. Air dryer does not purge or

exhaust air.

A. Faulty air dryer purge valve.

A. After determining air reaches purge valve control port by

installing a T-fitting with a pressure gauge into the governor

unloader port, repair purge valve if necessary.

B. See Causes B, E, and F for Symptom

#4.

B. Refer to Symptom 4, Remedies B, E, and F.

Also refer to Symptom 1, Remedy B.

7. Desiccant material being

expelled from the air dryer

purge valve exhaust (may

look like whitish liquid or

paste or small beads.)

A. Faulty dryer cartridge.

A. Replace the Bendix

®

AD-IS

®

air dryer cartridge or AD-IS air

dryer.

B. Excessive dryer vibration.

B. Check the AD-IS air dryer mounting for looseness or damage.

Repair the mounting and replace cartridge.

8. Unsatisfactory desiccant life. A. Excessive system leakage.

A. Refer to Symptom 1, Remedy A.

B. Wrong vehicle application for an

AD-IS

®

air dryer.

B. Refer to Symptom 2, Remedy C.

C. Compressor passing excessive oil. C. Check for proper compressor installation; if the symptoms

persist, replace the compressor. Refer to Bendix Advanced

Troubleshooting Guide for Air Brake Compressor (BW1971).