Symptom:

What it may indicate:

What you should do:

10.0 Air charging

system doesn’t

build air.

(a) Governor malfunction*.

(b) Restricted discharge line.

(c) Air dryer heater malfunction:

exhaust port frozen open.

(d) Compressor malfunction.

Go to Test 4 on page 15.

See 9.0(f).

Replace air dryer heater.

Replace the compressor only after making

certain the preceding conditions do not

exist.

11.0 Compressor

safety valve

releases air

(compressor builds

too much air).

(a) Restricted discharge line.

(b) Downstream air brake system

check valves or lines may be

blocked or damaged.

(c) Air dryer lines incorrectly installed.

(d) Compressor safety valve

malfunction.

(e) Compressor unloader mechanism

malfunction.

(f) Governor malfunction.

If discharge line is restricted:

 By more than 1/16" carbon build up,

replace the discharge line (see Table A,

Column 2, on page 3 for recommended

size) and go to Test 3 on page 14.

 By other restrictions (e.g. kinks).

Replace the discharge line. See Table A,

Column 2, on page 3 for recommended

size.

The discharge line must maintain a

constant slope down from the compressor

to the air dryer inlet fitting to avoid low points

where ice may form and block the flow.

If, instead, ice blockages occur at the air

dryer inlet, insulation may be added here,

or if the inlet fitting is a typical 90 degree

fitting, it may be changed to a straight or

45 degree fitting. For more information on

how to help prevent discharge line freeze-

ups, see Bendix Bulletins TCH-008-021

and TCH-008-022. Shorter discharge line

lengths or insulation may be required in cold

climates.

Inspect air lines and verify check valves are

operating properly.

Ensure discharge line is installed into the

inlet of the air dryer and delivery is routed

to the service reservoir.

Verify relief pressure is 250 psi. Replace if

defective.

Go to Test 6 on page 15.

Go to Test 4 on page 15.

Damaged

discharge

line shown.

* Note: For the Bendix

®

DuraFlo

596

air compressor, not only

the governor, but also the SV-1

synchro valve used would

need to be tested. See Bendix Bulletin TCH-001-048.