7

Symptom:

What it may indicate:

What you should do:

(e) Air compressor discharge and/

or air dryer inlet temperature too

high.

(f) Insufficient coolant flow.

(g) Restricted discharge line.

Check temperature as outlined in Test 3 on

page 14. If temperatures are normal go to

4.0(h).

Inspect coolant line. Replace as necessary

(I.D. is 1/2").

Inspect the coolant lines for kinks and

restrictions and fittings for restrictions.

Replace as necessary.

Verify coolant lines go from engine block to

compressor and back to the water pump.

Repair as necessary.

If discharge line is restricted or more than

1/16" carbon build up is found, replace the

discharge line. See Table A, column 2, on

page 3 for recommended size. Replace as

necessary.

The discharge line must maintain a

constant slope down from the compressor

to the air dryer inlet fitting to avoid low points

where ice may form and block the flow.

If, instead, ice blockages occur at the air

dryer inlet, insulation may be added here,

or if the inlet fitting is a typical 90 degree

fitting, it may be changed to a straight or

45 degree fitting. For more information on

how to help prevent discharge line freeze-

ups, see Bendix Bulletins TCH-008-021

and TCH-008-022. Shorter discharge line

lengths or insulation may be required in cold

climates.

Temperature

Other

Check compressor air inlet line for

restrictions, brittleness, soft or sagging

hose conditions etc. Repair as necessary.

Inlet line size is 3/4 ID. Maximum restriction

requirement for compressors is 25 inches

of water.

Check the engine air filter and service if

necessary (if possible, check the air filter

usage indicator).

(h) Restricted air inlet (not enough air

to compressor).

(g)

(h)

4.0 Oil in supply or

service reservoir*

(air dryer installed)

(continued)

(f)

(e)

(g)

Kinked discharge line shown.

Partly

collapsed

inlet line

shown.

Testing the temperature

at the discharge fitting.

Inspecting the coolant hoses.

*If a maintained Bendix

®

PuraGuard

®

system filter or Bendix

®

PuraGuard

®

oil coalescing filter is

installed, call 1-800-AIR-BRAKE (1-800-247-2725) option 2 and speak to a Tech Team member.