Pretest Procedures
Step
Procedure
E
1. Vehicle Ignition: Key-ON, Engine-OFF.
2 . Measure for J1939 data voltage on pins 6 and 5 of the DIU harness connector .
(J1939 Low to Ground)
a .
If the voltage is fluctuating between 0 to 3 volts .
i .
Proceed to Step F .
b .
If the voltage is a constant at 0 volts .
i.
Test Failed. Check for open/loose connections in the vehicle’s J1939 data link harness.
(See Note)
Note: Refer to vehicle OEM repair manual or contact the OEM for more information on the J1939 data link harness .
Pin #
Description
J1-5
Chassis Ground
J1-6
J1939-
6
Chassis
Ground
5
J1939-
Advertising