13

Pretest Procedures

Step

Procedure

E

1. Vehicle Ignition: Key-ON, Engine-OFF.

2 . Measure for J1939 data voltage on pins 6 and 5 of the DIU harness connector .

(J1939 Low to Ground)

a .

If the voltage is fluctuating between 0 to 3 volts .
i .

Proceed to Step F .

b .

If the voltage is a constant at 0 volts .

i.

Test Failed. Check for open/loose connections in the vehicle’s J1939 data link harness.
(See Note)

Note: Refer to vehicle OEM repair manual or contact the OEM for more information on the J1939 data link harness .

Pin #

Description

J1-5

Chassis Ground

J1-6

J1939-

6

Chassis

Ground

5

J1939-

Advertising