Component power supply test, Overview, Verifying ignition power to the diu – Bendix Commercial Vehicle Systems VORAD VS-400 INSTALLATION NOTES User Manual

Page 45

Advertising
background image

General Information

43

Appendix 4A

4. Component Power Supply Test

Overview

The base Bendix

VORAD

®

VS-400 system consists of two components, the FLR and DIU . Both should be powered by the main ignition

power supply (12 Vdc) . If one of these components is incorrectly connected to constant battery power or a secondary ignition source other
than the main ignition power supply bus, there is the potential for J1939 communication Diagnostic Trouble Code (DTC) between the FLR
and the DIU . These include, but are not limited to, Diagnostic Trouble Codes (DTCs) 32 and 33 . If these Diagnostic Trouble Codes (DTCs)
appear after the installation of a new VS-400 system or if the system is suspected of having this problem, perform this test to verify proper
ignition power source to the FLR and the DIU .

Verifying Ignition Power to the DIU

Step

Procedure

A

1.

Vehicle Ignition: Key-OFF, Engine-OFF.

2 .

Disconnect the 8-way connector from the back of the VS-400 Driver Interface Unit (DIU) .

3 .

Measure for zero voltage on pins 4 and 5 on the harness connector .

a .

If the voltage is 0 .5 volts or less .

i .

Proceed to Step B .

b .

If voltage is greater than 0 .5 volts but less than battery voltage .

i .

Test Failed . Check DIU power supply wiring for sources of stray voltage or shorts to voltage .

c .

If the voltage is within 0 .6 volts of the battery voltage measured in Step A .

i .

Test Failed . The DIU is improperly wired or shorted to a battery power source . Correct the
wiring by connecting the DIU to the main ignition power supply bus and repeat Step .

Advertising