General Information

17

Pretest Procedures

Step

Procedure

I

1. Vehicle Ignition: Key-ON, Engine-OFF.

2 . Measure for ignition voltage on pins 10 and 9 of the harness connector .

a .

If the voltage is within 0 .6 volts of the battery voltage measured in Step A .
i .

Proceed to Step J .

b .

If the voltage is less than 0 .6 volts of the battery voltage measured in Step A or open .

i.

Test Failed. Check component fuse. Troubleshoot power supply to the FLR for open/corroded
connections or shorts to ground and repeat Step .

Pin #

Description

10

9

Advertising