14

5. If the resistance is less than 10k Ohms, then disconnect

the main connector from the processor and recheck

the resistance on the blue wire. If the resistance is

still less than 10k Ohms then a short may exist in the

wiring harness (a screw may have been driven in to

the wire). If the resistance is greater than 10k Ohms

then temporarily replace the processor with a known

good unit and re-test.

6. Reconnect the main connector to the processor

and recheck the resistance on the blue wire. If the

resistance is greater than 10k Ohms then temporarily

replace the processor with a known good unit and

re-test

ADDITIONAL SUPPORT AT
WWW.BENDIX.COM/1-800-AIR-BRAKE (1-800-247-2725, OPTION 2)

For the latest information, and for free downloads of the Bendix

®

ACom

®

Diagnostics

software, and its User Guide, visit the Bendix website at: www.bendix.com.
For direct telephone technical support, the Bendix Tech Team is available at 1-800-AIR-

BRAKE (1-800-247-2725, option 2) Monday through Friday, 8:00 A.M. to 6:00 P.M. ET.

Follow the instructions in the recorded message.
The Bendix Tech Team can also be reached by e-mail at: [email protected].

3.5 CLEARING DIAGNOSTIC

TROUBLE CODES (DTCS)

Once the problem has been found and resolved, clear the

AutoVue

®

LDW system Diagnostic Trouble Codes (DTCs)

by cycling the ignition power.