Burst Average Power

Power Range

13 – 500 W average

Burst Width

1 μs – 5 ms

Repetition Rate, Min

5 Hz (with 12 dB Peak/Avg ratio)

Duty Cycle (D)**

0.02 to 1 (D = Burst Width / Period)

Measurement Uncert. ± (6% of reading + 166/D mW)

a

a. Above 35 °C or below 15 °C add 3%
** Duty Cycle and CCDF read out dependent on display

method.

Crest Factor

RF Power Range

500 mW to 500 W average, 13.3W
minimum peak

Measurement
Uncert.

Linear sum of peak and average power
uncertainty

Complementary Cumulative Distribution Function

(CCDF)

Measurement Range*

0.1 – 100%

Measurement Uncert.

± 2%

Threshold Level Range 13.0 W to 1300 W peak

Level Set Accuracy

As peak power uncert. + 2%