5019d specifications, Sensor characteristics – Bird Technologies 5019D-Manual User Manual

Page 53

Advertising
background image

41

5019D Specifications

Sensor Characteristics

Frequency Range

25 MHz to 1.0 GHz

RF Power Range

100 mW to 100 W average,
2.6 to 260 W peak

Maximum Power

See Figure

10 on page

25.

Impedance, Nominal 50 ohms
Insertion Loss, Max:

25 – 1000 MHz


0.05 dB

Input VSWR, Max:

25 – 1000 MHz


1.05

Directivity, Min:

25 – 100 MHz
100 – 1000 MHz


28 dB
30 dB

RF Connectors

N Female

Interface:

DPM

PC Serial Port

PC USB Port


Male DB-9, RS-232, 9600 Baud, no
parity, 8 data bits, 1 stop bit
Female DB-9, EIA-232, 9600 Baud,
no parity, 8 data bits, 1 stop bit
USB 1.1 interface

Power Supply:

DPM
USB Port
DC Connector


From host instrument via cable
less than one low-power USB load
7 – 18 Vdc, < 100 mA

Data Logging

In VPM software

Advertising