Bird Model 5000-EX Digital Power Meter

30

Bird 5011 and 5011-EF Terminating Sensors

General

Corrected terminated average
power

Sensor Type

Diode based terminated true
average power measurement

Frequency Range

5011
5011-EF

40 MHz to 4 GHz
40 MHz to 12 GHz

RF Power Range

10

µ

W to 10 mW

(–20 dBm to +10 dBm)

Max Power (Damage
Level)

2 W avg.
125 W peak for 5 µs

Peak/Average Ratio

12 dB max

Uncertainty

*

±(5% of reading ± 1 µW) (95% c.l.)
(excluding mismatch uncertainty)
(with correction factors for -EF)

RF Connector

5011
5011-EF

N Male
Precision N Male

Impedance, Nominal

50 ohms

Input VSWR:
5011

Typical
Maximum

5011-EF

Typical
Maximum

1.03 (36.6 dB return loss)
1.20 (20.8 dB return loss)

1.05 (32.0 dB return loss)
1.25 (19.1 dB return loss)

Power Supply

From host instrument via cable