16 // USER GUIDE

About Fall Detection

Loner IS is constantly monitoring your motion for falls. If Loner IS detects a fall, it will enter
the alarm mode and annunciate the low alarm pattern to indicate a pending Fall Detected
alert. If you do not require assistance, you have 30 seconds to cancel the alert.

Performance Expectations of the Fall Detection System
Loner IS utilizes the gyroscope and accelerometer to determine the motion of nor-
mal human activity and thus determines when an extreme event occurs, such as a fall.
Accuracy of the system depends on you wearing Loner IS correctly—on the belt at the hip.

Cancelling a Pending Fall Detected Alert

1. Press the acknowledge button for 1 second.

After one second, the alarm pattern will be silenced and Loner IS will return to
regular operation.

™

If you have not cancelled the alert within 30 seconds, the Fall Detected Alert is sent,
initiating the alert escalation process. Loner IS will annunciate the high alarm pattern
and will continue until the alert is canceled or the battery is depleted.

Cancelling a Fall Detected Alert

1. Press and hold the acknowledge button for 3 seconds.

After three seconds, the alarm pattern will be silenced and the Loner IS will return to
regular operation.

™

If the user cancels a fall detected alert, this does not clear the alert within the Loner
Portal user account. Monitoring personnel are required to address the safety incident.

About Checking In

Loner IS can be configured in Loner Portal to have you periodically check in. During the
Check-in period, Loner IS will enter the alarm mode and annunciate the low alarm pattern
to indicate a pending Missed Check-in alert. If you do not require assistance, you have 30
seconds to cancel the alert.

Cancelling a Pending Missed Check-in Alert:

1. Press the acknowledge button for 1 second.

After one second, the alarm pattern will be silenced and Loner IS will return to
regular operation.

™

If you have not cancelled the alert within 30 seconds, the Missed Check-in Alert is sent,
initiating the alert escalation process. Loner IS will annunciate the high alarm pattern
until the alert is cancelled or the battery is depleted.