TROUBLESHOOTING (cont.)

Beverage overflows dispenser

Weak beverage

1.Dispenser

2. Brew Timer

3. Brew Solenoid Valve

4. Dilution Timer

5. Dilution Solenoid Valve

1. Filter Type

2. Tea

3. Sprayhead

4. Funnel Loading

5. Water Temperature

The dispenser must be completely
empty before starting a brew cycle.

Refer to

Service -

Brew Timer for

testing procedures. See page 17 or
18

Remove the Brew Solenoid Valve
and clean any obstruction. Rebuild
or replace the valve if necessary.
See page 15

Refer to

Service

- Dilution Timer for

testing procedures. See page 22

Refer to

Service

- Dilution Solenoid

Valve for testing procedures. See
page 21

BUNN

®

paper filters must be used

for proper extraction.

A sufficient quantity of fresh, loose
tea leaves should be used for proper
extraction.

A six-hole stainless steel spray-
head must be used for proper ex-
traction.

The BUNN

®

paper filter must be

centered in the funnel and the bed
of tea leaves leveled by gentle shak-
ing.

Place an empty funnel into the fun-
nel rails on the brewer. Initiate a
brew cycle and check the water
temperature immediately below the
sprayhead with a thermometer. The
reading should not be less than
200°F(93°C). Adjust the control
thermostat to increase the water
temperature. Replace if necessary.

REMEDY

PROBABLE CAUSE

PROBLEM

10145 072600

Advertising
This manual is related to the following products: