TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Brew cycle will not start (cont.)

Water is not hot

Dilution cycle will not start

5. Start Switch

6. Brew Timer

7. Brew Solenoid Valve

8. Internal Flow control (.195 GPM)

1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat or thermal
cut-off. Use only BOM replacement
part #29329.1000

2. Control Thermostat

3. Tank Heater

1. (A) ON/OFF Switch (T3)

(B) Selector Switch (T6)

2. Start Switch

3. Dilution Timer

Refer to

Service

- Start Switch for

testing procedures. See page 26

Refer to

Service

- Brew Timer for

testing procedures. See page 17 or
18

Refer to

Service

- Brew Solenoid

Valve for testing procedures. See
page 15

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the flow control and
check for obstructions. Clear or re-
place.

Refer to

Service

- Limit Thermostat

for testing procedures. See page 23

Refer to

Service

- Control Thermo-

stat for testing procedures. See
page 20

Refer to

Service

- Tank Heater for

testing procedures. See page 27

Refer to

Service

- ON/OFF Switch

for testing procedures. See page 24

Refer to

Service

- Selector Switch

for testing procedures. See page 24

Refer to

Service

- Start Switch for

testing procedures. See page 26

Refer to

Service

- Dilution Timer for

testing procedures. See page 22

10145 072600