Re-adjusting the c/port, Locking out mass-storage devices, Figure 37 – ClearCube R Series Pentium 4 User Manual

Page 91

Advertising
background image

ClearCube Product Manual and Installation Guide

User Port Installation • 81

along the left side of the screen has been eliminated, re-adjust the sharpness control for

the best image. This completes the tuning procedure for the C/Port.

Re-adjusting the C/Port

If, during the adjustment procedure, you become lost or confused, it is best to just

start over again. Begin by resetting the color switches to the Off positions. Do this by

adjusting each switch, one at a time, until it turns the picture off and then advance the

switch by one position, to Position 1. When you complete this, each switch will be

returned to the start position as shipped (see Figure 36). Finally, turn the sharpness

control fully counter-clockwise. From this point you can go back to the beginning and

start the tuning procedure over again. Moving the C/Port to a new location may

require re-adjustment of the C/Port unit.

Locking out Mass-Storage Devices

When using ClearCube’s C/Ports, you have an additional feature that provides

increased levels of security. The R Series PC Blades offer a unique Mass Storage

Lockout (MSL) security feature that disables the use of any USB mass storage device

at the desktop (e.g., key drives, floppy drives, CD-ROM drives, etc.). The default

factory setting does not enable this security feature – thus in the default mode, any

USB device, including mass storage devices connected to the C/Port, will be

recognized by the operating system. However, Switch Manager allows setting MSL in

software to lock out the use of storage devices.

To enable MSL in hardware, a jumper on the PC Blade needs to be moved from

the default position to the adjacent position. You will need a set of needle-nose

pliers to access the MSL jumper.

See Figure 37 and Figure 38 for the jumper locations by Blade model number.

The default position for the jumper connects pins 2 and 3 (USB mass storage

devices will function normally).

When the jumper is in the default position, you can also use a software setting to

disable mass storage devices. This software setting is accessible through the

Switch Manager software.

NOTE: When the MSL jumper is physically set to lock out mass storage devices, the

software cannot override this.

Figure 37 Model R1200 Mass Storage Lockout Jumper Location and Setting

Advertising