Banner QMT72 Rope Pull Switches User Manual

Page 2

Advertising
background image

Model

Max. Rope

Length

Run Position

Cable Pulled

Cable Break

Switching Diagram

RP-QMT72D-20L

20 m (65 ft)

25

26

13

14

25

26

13

14

25

26

13

14

13-14

25-26

Break

Pull

50N

180N

0 (0)

2 (0.08)

11 (0.43)

13 (0.51)

mm (in)

NOTE: This symbol

for a positive-opening safety contact (IEC 60947-5-1) is used in the switching

diagram to identify the point in actuator travel where the normally-closed safety contact is fully open.

Model

Max. Rope

Length

Run Position

Cable Pulled

Cable Break

Switching Diagram

RP-QMT72F-12L

12 m (40 ft)

25

26

45

46

13

14

33

34

25

26

45

46

13

14

33

34

25

26

45

46

13

14

33

34

26

14

13-14

25-26

Break

Pull

80N

200N

0 (0)

2 (0.08)

6 (0.24)

8 (0.32)

mm (in)

33-34

45-46

Break

Pull

RP-QMT72E-12L

12 m (40 ft)

25

26

13

14

33

34

25

26

13

14

33

34

25

26

13

14

33

34

13-14

25-26

Break

Pull

80N

200N

0 (0)

2 (0.08)

6 (0.24)

8 (0.32)

mm (in)

33-34

AUX

Contacts:

Open

Closed

Transition

NOTE: This symbol

for a positive-opening safety contact (IEC 60947-5-1) is used in the switching

diagram to identify the point in actuator travel where the normally-closed safety contact is fully open.

Rope Pull Switches

2

www.bannerengineering.com - tel: 763-544-3164

P/N 62084 Rev. C

Advertising