Installation Instructions - Single Hole and Cover Plate

3

Installation Instructions

Aerada 1000 Series Gooseneck Faucet

Bradley Corporation • 215-1559 Rev. A; EN 04-216A

9/23/04

1

2

3

4

7a

5

6

8

Remove the locknut (1), washer
(2), stilt washer (3) from the
spout shank (4). Remove shank
from cover plate (if supplied).

Install stilt washer (1) all
the way up onto shank,
crown side up. Position
sensor cable (2) through
one of the rounded slots
in the stilt washer (1).

If faucet was installed with
cover plate, secure cover plate
with basin washers (1), flat
washers (2) and locknuts (3).

Install the shank washer (1)
and locknut (2) onto faucet
shank. Tighten locknut
securely to prevent collar and
spout from rotating. If
necessary, support spout base
from above to prevent twisting.

Install spout nut (1) onto the
spout.

For swivel mount, only install
two plastic split washers (2).

For rigid mount, only install
1/8" thick plastic washer (3).

Mount the spout completely
into the base and securely
tighten the spout nut (1).

Attach the outlet assembly (1) and aerator
gasket (2) to the spout. The outlet assembly
is equipped from the factory with a 0.5 GPM
cartridge (white screen). To configure the
outlet with the 2.2 GPM cartridge (yellow
screen) refer to step 8.

IMPORTANT: If 0.5 GPM spout is to
be used, skip Step 8 and proceed
directly to

Installation - Solenoid

and Optional Valves, page 4.

To convert outlet assembly to 2.2 GPM:

1. Disassemble outlet assembly using key (1).
2. Remove the 0.5 GPM cartridge (white screen) and replace it with the

2.2 GPM cartridge (2).

3. Install the rubber washer (3), adapter (4) and aerator gasket (5).

IMPORTANT: Proceed directly to

Installation - Solenoid and

Optional Valves, page 4.

Install faucet assembly
into deck hole.
Use plumbers putty
to seal faucet to deck.

4

3

2

3

1

1

1

2

3

4

5

2

2

2

2

1

3

1

1

1

2

Be careful not to
nick or cut the
sensor cable during
installation.

CAUTION: Flush water lines
before beginning this step.

7b

Attach the plain spray ring (1) to the spout. Insert
the laminar flow control insert (2) into the spout.

IMPORTANT: If laminar flow is to be used,
skip Step 8 and proceed directly to
Solenoid and Optional Valves, page 4.

1

(269-1814)

IMPORTANT: Flow rates exceeding the
0.5 GPM maximum limit for public
lavatories set by ASME A112.18.1
negate the UPC certification of this
faucet for public use applications.

For applications requiring laminar
flow without an aerator, refer to the
instructions below.

2

(269-1815)

IMPORTANT: Flow rates exceeding the 0.5 GPM maximum limit
for public lavatories set by ASME A112.18.1 negate the UPC
certification of this faucet for public use applications.