Bradley Smoker AERADA 1000 Series S53-307 User Manual

Page 5

Advertising
background image

Installation Instructions - Electronic Battery Box (DC)

Models S53-306 and S53-307

CAUTION: Faucet will automatically calibrate when

sensor cable is connected. DO NOT place
objects in front of collar sensor for first 30
seconds after power-up.

5

Installation Instructions

Aerada 1000 Series Gooseneck Faucet

Bradley Corporation • 215-1559 Rev. A; EN 04-216A

9/23/04

1

Install the baseplate and mount the electronic box to the
desired wall location. The baseplate must be mounted either
level with or above solenoid valve, and within 12" of the
solenoid valve.

NOTE: When positioning
the baseplate, make sure
there is enough room for
drip loops in the final
installation. Refer to Note
in step 6.

2

Remove the strain relief cover and screw (1) using hex
key provided (2) . Remove foam gasket (3). Separate the
foam gasket at the perforation.

1

3

2

4

Insert larger foam gasket (1). Attach strain relief cover (2)
and screw (3) using hex key provided (4).

1

2

3

4

5

Mount the electronic box to the wall location using
screw(1) and hex key provided (2).

NOTE: To ensure the
electronic box is level
with or above the
solenoid valve, the cables
should create a drip loop
The electronic box is
designed with the wire
connectors facing
downward to ensure
proper drip loops.

1

2

3

Insert smaller foam gasket (3) into the strain relief. Install
solenoid cable plug (1) into the smaller, telephone-style
jack in the transformer. Install faucet sensor cable plug (2)
into the larger RJ-45 jack.

1

2

3

CAUTION: DO NOT turn on water supply until all

electrical connections are made.

6

Turn on the water supply.

NOTE: When power is initially supplied, the LED on the
electronic box will blink and an audible indicator chirps twice per
second whenever hand presence is detected. This will continue
for 8 minutes and then stop.

Proceed to Faucet Operation, page 6.

Advertising