Aerada 1000 Series Gooseneck Faucet

Installation Instructions

4

9/23/04

Bradley Corporation • 215-1559 Rev. A; EN 04-216A

Installation Instructions - Solenoid Valves and Electronic Box (AC)

Models S53-308 and S53-309

1

Thread the union nut (1) of the solenoid assembly to the
faucet shank (2). Use Teflon tape on the threads to
ensure a leak-free joint. Make sure the solenoid is
positioned for easy access. Tighten the union nut.

1

2

CAUTION:

Do not use pipe
dope on threads.
The solenoid could
become
contaminated and
will void any
warranty.

2

When installing the transformer, make sure the electrical box
is located within 6' of the sink. Install the baseplate and mount
the electronic box to the desired wall location. The baseplate
must be mounted either level with or above the solenoid
valve, and within 12" of the solenoid valve. Make sure the
transformer wires (1) are positioned in the baseplate channel
(2) before mounting the unit.

1

2

NOTE: When
positioning baseplate,
make sure there is
enough room for drip
loops in final
installation. See Note in
step 7.

3

Remove the strain relief
cover and screw (1)
using hex key provided
(2). Remove both foam
gaskets (3). Separate
the foam gaskets at the
perforation.

1

3

2

CAUTION: Do not attempt to operate multiple

faucets using a single transformer.

4

Insert smaller foam gasket (3) into strain relief. Install
solenoid cable plug (1) into the smaller, telephone-style
jack in the electronic box. Install faucet sensor cable plug
(2) into the larger RJ-45 jack.

1

3

2

5

Insert larger foam gasket (1). Attach strain relief cover (2)
with screw (3) using hex key provided (4).

1

2

4

3

6

CAUTION: Faucet will automatically calibrate when sensor

cable is connected and power is supplied. DO
NOT place objects in front of collar sensor for
first 30 seconds after power-up.

Feed the wires from the transformer through the baseplate.
Connect the 1/4" spade terminal to the positive (+) terminal
and connect the 3/16" spade terminal to the negative (-)
terminal. Terminals are two different sizes and match
corresponding terminal clips from transformer.

NOTE: The faucet will
automatically calibrate when
sensor cable is connected
and power is supplied.
Refer to step 8.

7

NOTE: To ensure the
electronic box is level
with or above the
solenoid valve, the
cables should create a
drip loop. The
electronic box is
designed with the wire
connectors facing
downward to ensure
proper drip loops.

2

1

Re-attach the electronic box to the baseplate location
using screw(1) and hex key provided (2).

8

CAUTION: DO NOT turn on water supply

until all electrical connections
are made.

Plug the transformer into the applicable electrical receptacle.

Wait at least 30 seconds, then turn on the water supply.

NOTE: When power is initially supplied, the LED on the electronic
box will blink and an audible indicator chirps twice per second
whenever hand presence is detected. This will continue for 8
minutes and then stop.

Proceed to Faucet Operation, page 6.