Dimensions, Bw3 models, Ratings and capacities – Bryant BW1 User Manual

Page 12

Advertising
background image

—12—

DIMENSIONS

BW3 MODELS

29

23

25

1

4

23

1

4

5

5

8

5

5

8

1

3

4

7

A

GAS
VALVE

INT. PILOT
CONTROL

PRESSURE
SWITCH

BLOWER

VENT
CONNECTOR

COMBINATION
LIMIT & RELAY
CONTROL

1

1

4

″ SUPPLY

RELIEF
VALVE

BURNER

TEMP

PRESSURE

GAGE

1

1

4

″ RETURN

CIRCULATOR

LEFT SIDE

RIGHT SIDE

FRONT

DIMENSIONS (In

.)

*

With factory-supplied adapter installed.

UNIT SIZE

A

VENT CONNECTION

042

11

4

*

075

14-1/4

4

*

112

17-1/2

4

*

150

20-3/4

4

*

187

24

4

*

225

27-1/4

4

*

CLEARANCES (In.

)

*

Service clearance requirement 24 in.

RIGHT SIDE

6

*

LEFT SIDE

6

TOP

6

BACK

6

FRONT

6

*

RATINGS AND CAPACITIES

*

*

Gas input ratings are for elevations up to 2000 ft. For elevations above 2000 ft, reduce input 4% for each 1000 ft above sea level.

† Selection factors providing for piping loss and starting load are those recommended by the Institute of Boiler and Radiator Manufacturers. Net water boiler

ratings are based on an allowance of 1.15.

‡ In accordance with U.S. Government test procedures.

UNIT

GAS

TYPE

MAX INPUT

(BTUH)

RATINGS
HEATING

CAPACITY‡

AFUE %

NET RATING

BOILER

WATER

CAPACITY

(GALLONS)

APPROX

SHIP.

WT (Lb)

Btuh

Btuh†

BW3AAN042

Natural

42,500

36,000

84.4

31,000

1.75

211

BW3AAN075

Natural

75,000

63,000

83.4

55,000

3.00

263

BW3AAN112

Natural

112,500

94,000

83.0

82,000

4.25

320

BW3AAN150

Natural

150,000

125,000

82.7

109,000

5.50

369

BW3AAN187

Natural

187,500

155,000

82.3

135,000

6.75

418