DIMENSIONS

MODEL BW9

ALTERNATE SUPPLY
& RETURN OPENINGS
(1-1/4" NPT (31.75mm)

CONNECTIONS
PROVIDED INSIDE
BOILER CABINET)

ACCESS PANEL

ALTERNATE OPENING
FOR GAS SUPPLY

BOILER WATER TEMPERATURE
& PRESSURE GAUGE

FRONT PANEL DOOR PULL

LEVELING FEET

CONDENSATE
DRAIN FITTING

(1/2" PVC) (12.7mm)

OPENING FOR RELIEF VALVE
DISCHARGE PIPE

OPENING FOR AIR
VENT AND EXPANSION
TANK CONNECTION

ALTERNATE BOILER WATER SUPPLY AND
RETURN (31.75mm)

CONNECTIONS

(1-1/4" NPT

BOILER CABINET)

PROVIDED INSIDE

DRAIN

VENT CONNECTION

(2" CPVC) (50.8mm)

5" (127mm)

JUNCTION BOX FOR 120 V POWER,
120 V CIRCULATOR BEADS, AND
24 V THERMOSTAT LEADS

VENT CONNECTION

(2" CPVC) (50.8mm)

ALTERNATE GAS
SUPPLY OPENING

ALTERNATE OPENING FOR
VENT TEE

GAS SUPPLY
OPENING

(1/2" NPT) (12.7mm)

COMBUSTION AIR
INTAKE FITTING

(2" PVC) (50.8mm)

STANDARD BOILER WATER
SUPPLY & RETURN OPENINGS

(1-1/4" NPT (31.75mm) CONNECTIONS
PROVIDED INSIDE BOILER CABINET)

A99156

RATINGS AND CAPACITIES

*

*

Gas input ratings are for elevations up to 2000 ft. In the USA, for elevations above 2000 ft., reduce input per the charts supplied in the high altitude derate kits.
In Canada, boilers may be used at high altitude by using a certified field conversion kit.

UNIT

GAS

TYPE

MAX INPUT

(BTUH)

HEATING

CAPACITY (BTUH)

AFUE %

NET RATING

Btuh†

BOILER

WATER

CAPACITY

(GALLONS)

APPROX

SHIP.

WT (Lb)

BW9AAN050

Natural

50,000

45,000

90

39,000

2.6

220

BW9AAN075

Natural

75,000

68,000

90

59,000

2.6

220

BW9AAN100

Natural

100,000

90,000

90

78,000

2.6

220

CLEARANCES

*

Service clearance requirement 24-in.

UNIT

COMBUSTIBLE (in.)

ACCESSIBILITY/CLEANING (in.)

SERVICING (in.)

TOP

1

8

8

LEFT SIDE

1

24

24

RIGHT SIDE

8

BASE

1

FRONT

0

24

24

BACK

1

INTAKE/VENT PIPING

0

NEAR BOILER HOT WATER PIPING

1