21

CHAPTER 5: Self-Test and Diagnostics

To run the self-test and diagnostics

program:

1. Copy the SETDIAG.* files from

the supplied network drivers
diskette into the network
directory.

2. At the network directory

prompt, type the following
command:

setdiag

The “setdiag” command may be
entered with special command
line parameters, as follows:

e—supports EPP mode

u—force unidirectional mode

c—force colors (default is
monochrome) when color
display is available

?—display a Help screen

3. The SETDIAG main menu is

displayed with a list of topics. To
select a topic, use the up and
down arrow keys to highlight
your choice, and press the Enter
key.

5.1 Diagnostics

The diagnostics program verifies
that the adapter has been properly
connected, executes several self-test
routines, and displays the following
information:

• LPT port number and address

• IRQ line used (if any)

• Interrupt line polarity of the

parallel port

• Data transfer method

(unidirectional or bidirectional)

• Node address

• Model name and hardware

version

• Date of manufacture

• Serial number

If the Adapter is not properly

connected or not powered, the
following message is displayed:

Adapter not connected, not powered
or driver already loaded.

This message will also be displayed if
one of the pocket adapter drivers is
loaded. In this case, unload the
driver or reboot the PC.

5. Self-Test and Diagnostics