All joints should be tight to avoid leaks.

The male end of each duct section

must point away from the dryer.

Whether connecting to an existing

venting system or a new venting

system, make sure that all ducting is

clean and free of lint.

The maximum permitted length for both

rigid and flexible metal duct is shown in

the table below.

Number of

90° Turns

or Elbows

Rigid Duct

Flexible Duct

0

66 ft.

(2011 cm)

45 ft.

(1372 cm)

1

56 ft.

(1707 cm)

36 ft.

(1097 cm)

2

48 ft.

(1463 cm)

29 ft.

(884 cm)

3

39 ft.

(1189 cm)

22 ft.

(671 cm)

4

30 ft.

(914 cm)

16 ft.

(488 cm)

Note:

Side and bottom exhaust installations

have a 90° turn inside the dryer. To

determine maximum exhaust length,

add one 90° turn to the chart.

More than two 90° turns are not

recommended. For best performance,

separate all turns by at least 4 ft. of

straight duct, including distance

between last turn and exhaust hood.

Exhaust vent hood

The exhaust duct must end with an

approved exhaust vent hood with

swing out damper(s). DO NOT use an

exhaust vent hood with magnetic

latches.

To avoid exhaust restriction, the outlet

must be a minimum of 12 inches (30

cm) above ground level or any other

obstructing surface.

Required parts

The parts required for the exhaust air

system (elbows, lines, exhaust air

outlets) are not included in standard

delivery of the dryer.

Accessories

The parts required for the exhaust air

system can be obtained from customer

service or your local dealer. Please

follow the installation instructions

supplied by the appropriate

manufacturer!

Side exhaust kit

part no. WTZ 1265

Note:

The maximum permitted number of 90°

elbows (including this side exhaust kit)

is four!

i

Special tool for cutting the hole in

prepared side panel is required.

Contact local dealer!

Bottom exhaust kit

part no. WTZ 1270

Note:

The maximum permitted number of 90°

elbows (including this side exhaust kit)

is four!

Left hinge kit

part no. WTZ 1260

The door catch can be reversed if

necessary. The door is hinged on the

right at the factory.

Pedestal Mounting Kit

part no. WTZ 1295

If mounting the dryer on the pedestal

follow the instructions supplied with the

pedestal.

Installation ć step by step

1. Unpack the dryer.

2. Remove all objects from the drum.

3. Check the dryer for visible

damage.

4. Position the dryer near the

installation location.

5. If required, change the door hinges

to the left

(see page 5).

6. If required install the exhaust air

outlet on the dryer

(see page 7).

7. Have the power supply cord fitted

by an authorized technician (see

page 8).

8. Install exhaust duct, if necessary.

Follow the installation instructions

supplied by the appropriate

manufacturer!

i

If space is very restricted, it is

recommended to fit the initial parts

of the exhaust duct to the dryer

before the dryer is moved to its

final installation location.

9. Move the dryer to its final location

and align.

CAUTION

Do not slide dryer across the

floor if heightĆadjustable feet

have been extended. Feet and/or

dryer base may be damaged if

dryer is slid across floor with

heightĆadjustable feet extended.

10. Position and then level the dryer

.