Lamp switches ballast power – Kino Flo BarFly 200D User Manual

Page 8

Advertising
background image

8

Lamp Switches

Ballast Power

Cold Temperature Operation

The BarFly is designed to operate at temperatures from 14F to 122F (-10C to +50C).

In cold temperatures, the fixture may not strike the lamp(s). Switch the fixture to OFF.

Make sure the onboard dimmer is full up and re-strike.

Once operating for a few minutes, the Lamps should re-strike instantly.

It is normal for the lamp to require a few minutes to achieve full light output even at

room temperature.

Troubleshooting

If the fixture does not strike after two or three attempts, turn off the fixture.

With the power switch in the ON position, the red light should be on. If it is not,

Voltage is not present. Check your power feed. The onboard dimmer should be full up,

turned completely clockwise. All lamp switches should be in the ON position.

Check lamp contact. Once everything has been checked, re-strike.

Warning! To Ensure Proper Operation

ALWAYS TURN OFF THE FIXTURE BEFORE

connecting or disconnecting lamps. After the lamps are

properly installed, the in-line switch can be turned on.

The BarFly fixtures require 100-240VAC 50/60 Hertz

on an earth grounded circuit. The electronic Ballast

operates at a high frequency of 47kHz. The BarFly is
lightweight, flicker-free and dead-quiet.

The BarFly 200D has two Lamp Switches. Turning off 1 lamp

equals a one f-stop reduction in light output without color shift.

Advertising