Positioning the range – La Cornue CornuFé 44 User Manual

Page 24

Advertising
background image

INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

22

ArtNo.280-0001 36” wide oven dimensions

Min 435/16” (110 cm) - 4311/16“ (111 cm)

For Canada, min 445/16” (112.5 cm)

Min 31½” (80 cm)

between the top of the cooktop

and a horizontal combustible surface

Maximum 13”

(33 cm)

Min 435/16” (110 cm) - 4311/16“ (111 cm)

recommended to allow for moving the range.

For Canada, min 445/16” (112.5 cm)

For electrical and

gas supply zone

Min 35 13⁄16” (91cm)

Max 36 7/8” (93.7cm)

6” (15.2 cm)

Gas shut-off

valve

Electrical

outlet

Minimum 18”

(46 cm)

Fig.7-1

Fig.7-3

Positioning the Range

Fig.7-1 and Fig.7-2 show the minimum recommended

distances and clearances from the range to nearby surfaces.
You must provide adequate clearances between the range

and adjacent combustible surfaces. These dimensions must

be met for safe use of your range.
The location of the electrical outlet and pipe opening (see

Gas Pipe and Electric Outlet Locations) may be adjusted to

meet specific requirements.
A gap of at least 3” (7.5 cm) should be left between each

side of the range ABOVE the cooktop level and any adjacent

vertical surface.
The cooktop surround should be level with, or above, any

adjacent work surface.
For non-combustible surfaces (such as unpainted metal or

ceramic tiles) the gap each side can be reduced from 3” to 1”

(2.5 cm).
A minimum space of 31½” (80 cm) is required between the

top of the cooktop and a horizontal combustible surface. The

maximum depth for cabinets installed above cooktops is 13’’

(33 cm).
The depth of the range is 28

3

/

8

’’ (72 cm) overall (Fig.7-3).

Any range hood should be installed in accordance with the

hood manufacturer’s instructions.
*Any splashback must be fitted in accordance with the

manufacturers instructions. Allowance should be made for the

additional height of the flue trim, which is fitted to the cooker

hob.
For safety reasons curtains must not be sited immediately

behind the range.
We recommend a gap of 43

11

/

16

” (111 cm) (for Canada 44

5

/

16

(112.5 cm)) between units to allow for moving the range.
If a flush fit is required (USA only), install the range up to the

unit at one side then install the unit the other side.

*

Fig.7-2

Advertising