Pressure testing – La Cornue CornuFé 44 User Manual

Page 40

Advertising
background image

INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

38

Make sure the inner

rail is forwards

ArtNo.102-0011 - Pressure test point

Pressure Testing

Connect the appliance to the gas supply. Check the appliance

is gas sound.
The gas pressure can be measured at the pressure test point

on the appliance side of the pressure regulator (Fig.8-11).
For proper operation, the pressure of LP supplied to the

regulator must be between 10’’ and 13’’ of water column

(2.49 – 3.24 kPa).
When checking for proper operation of the regulator, the

inlet pressure must be at least 1’’ (0.25 kPa) greater than the

operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the range

manifold must remain in the supply line regardless of

whether natural or LP gas is being used.

To Fit the Storage Drawer

Slide the inner side rails out until fully extended (Fig.8-12).
Lift the drawer at its sides and locate one of the drawer rails

(approximately 15 mm) onto an inner side rail (Fig.8-13).
Rotate the drawer to locate the remaining drawer rail onto

the opposite inner side rail.
Carefully slide the drawer back into the cavity. Some

resistance will be felt as the drawer rails locate fully onto the

inner side rails.

nn

Check the appliance is gas sound.

nn

DO NOT use a flame to check for gas leaks.

When using test pressures greater than ½ psig to pressure

test the gas supply system of the residence, disconnect the

range and individual shut-off valve from the gas supply

piping. When using test pressures of ½ psig or less to test

the gas supply system, simply isolate the range from the gas

supply system by closing the individual shut-off valve.

nn

Check the operation of all the burners.

Fig.8-11

Fig.8-12

15 mm

Approx.

Fig.8-13

Advertising