5

CONTROL PANEL AND BASIC OPERATION:

Power Input:

The power required to operate the PowerLight PLR300DR, PLR1250DR or PLR2500DR
is 105 to 125 volts AC, 60 Hz, 10 Amp. The power cord has a 125V, 10 Amp. rating.
The PowerLight Export models (PLRX1250DR and PLRX2500DR) are rated 230 volts
AC, 50 Hz, 10 Amp and have a 230V power cord with a German/European plug.
Replacement cords or extension cords rated for less amperage may overheat and should
not be used with PowerLights.

Circuit Protection:

Circuit protection automatically protects this appliance from excessive damage due to
circuit or component failure. Operation exceeding the rated cycle of the appliance may
cause the fuse to open. [Always replace fuse with same rating of fuse.] An additional
thermal protector is located inside the PowerLight and may open, if the rated duty cycle
is exceeded. A cooling off period of 3 to 5 minutes is required to reset the thermal fuse.

To replace a blown fuse (power cord must be disconnected), simply unscrew the fuse
holder cap (bottom of unit) and replace the exposed fuse with a new fuse. If fuses
continue to blow, contact your dealer or qualified service person. (See specification
section for fuse replacements)