1 dismantling the slide-in unit, 4 dismantling the drive unit oil bath lubrication, Dismantling the slide-in unit – Richter MNK Series User Manual

Page 17: Lubrication, Grease lubrication, Dismantling the drive unit oil bath lubrication17, Series mnk

Advertising
background image

Series MNK

Page 17

9230-050-en

Revision 11

TM 7903

Edition 07/2010

Axial forces

are produced when the plain bearing

pedestal is pulled out of the bearing pedestal. These
forces diminish again abruptly after it has been
removed.
The operating torque of the magnetic coupling
installed is specified on the

type plate

.

7.6.1 Dismantling the slide-in unit

Secure slide-in unit on the work bench or a work
top.
Pull the plain bearing pedestal

339

out of the

bearing pedestal.

Caution!

Magnetic forces!

Risk of accident !

If necessary loosen the centering of the plain
bearing pedestal using a rust dissolver and levers.

It is imperative to use clamping jaws with
a rubber surface.

Clamp the plain bearing pedestal

339

with the

sealing surfaces in a vice.
Undo the impeller

230

and inner magnet

assembly

859

with a strap wrench.

Right-hand

thread !

Pull parts out of the plain bearing pedestal

339

or

off the pump shaft

211

.

Make sure that no parts of the plain
bearing fall. Silicon carbide is easy to
break.

Keep bearing sleeves

529

and bearing bushes

545

in pairs which belong together.

Clamp pump shaft

211

with the flat pivot point in a

vice. Use

smooth clamping jaws

.

Undo impeller

230

or inner magnet assembly

859

(depending on which part has remained on the
pump shaft).
If the bearing bushes

545

have to be removed

from the plain bearing pedestal, a Richter jig is
best suited for this purpose. See assembly aids in

Section 10.3

.

To dismantle the can

159

, can insert

158

,

intermediate ring

509

and support ring

518,

loosen the centering of the support ring

518

on

the side recesses in the bearing pedestal

330

.

Pull parts out of the bearing pedestal

330

.

Only separate can

159

and can insert

158

if one

part has to be replaced. If separation is not
possible, the unit must be cooled to approx. 5 °C.
In the case of a vacuum-proof design the can
insert is glued to the can. Separation is not
possible without destroying the can.
In the case of a can with a can monitor using a
flexible p.c. board, dismantling is possible. We
recommend you, to have the reassembly be
performed at the manufacturer's.

7.6.2 Dismantling the drive unit

Long life grease lubrication

Remove circlip

932/3

on the motor side.

Remove rear bearing cover

361

. Use groove for

dismantling.
Remove circlip

932/2

.

Press drive shaft

213

with drive magnet assembly

858

out of the bearing pedestal.

Remove radial ball bearings

321/1

.

Remove second circlip

932/1

.

Remove distance sleeve

525

and second radial

ball bearing

321/2

.

Dismantling can be checked using the sectional
drawing in

Section 9.2

and the components

available.

7.6.3 Changing the radial ball bearings

Long life grease lubrication

To change the radial ball bearings

321,

perform

dismantling as described in

Section 7.6

.

Pull the plain bearing pedestal

339

out of the

bearing pedestal. See

Section 7.6.1

.

The plain bearing pedestal with impeller, inner
magnet assembly and pump shaft need not be
dismantled.

The rest dismantheling see

Section 7.6.2

.

Change radial ball bearings

321

.

Assembly as described in

Section 7.8

.

7.6.4 Dismantling the drive unit

Oil bath lubrication

Remove hex. screw

901/4

and drain oil.

Remove hex. socket screw

914/1

with spring

washer

934/2

for the bearing cover. For this

purpose assembly bores are provided in the drive
shaft

213

for a hex. socket screw key.

Remove circlip

932/3

on the motor side.

Remove rear bearing cover

361

with shaft seal

421/1

and O-ring

412/1

. Use groove for

dismantling.
Remove circlip

932/2

.

Press the drive shaft

213

with drive magnet

assembly

858

out of the bearing pedestal.

Remove radial ball bearings

321/2

from the

bearing pedestal.
Remove circlip

932/1

.

Remove distance sleeve

525

, radial ball bearings

321/1

, O-ring

412/5

and bearing cover

360

using

an extractor.
Dismantle drive magnet assembly

858

and drive

shaft

213

.

Advertising