Relevant documents, 1 technical data, Technical data – Richter MNK Series User Manual

Page 3: 1technical data, Series mnk

Advertising
background image

Series MNK

Page 3

9230-050-en

Revision 11

TM 7903

Edition 07/2010

Relevant documents

Data sheet
Works certificate
Sectional drawing
MNK greased for life

9230-00-3000

MNK oil bath lubrication

9230-00-3012

Installation drawing
MNK assembly drawing (grease)

9230-00-3011

MNK assembly drawing (oil bath)

9230-00-3012

Performance curves
Spare parts list
Operating manual and declaration of conformity
motor *
Operating manual and declaration of conformity
coupling *
Supplementary Installation and Operating Manual
for external flushing

9230-060-en *

Supplementary Installation and Operating Manual,
vortex pump

9230-061-en *

Supplementary Installation and Operating Manual,
„self-priming“ design

9230-062-en *

*

if

contained in the scope of delivery

Appendix to the operating instructions

Operational limits 9200-00-0030
Declaration of conformity with ATEX
Declaration of conformity without ATEX
Form for Safety Information Concerning the
Contamination QM 0912-16-2001_en

On request:

Magnetic drive data Richter TIS 0543-03-0001
Publication: "Centrifugal Pump Operation without
NSPH Problems"
Publication "Safe Operation of Magnetic Drive
Pumps“

1

Technical data

Manufacturer :

Richter Chemie-Technik GmbH
Otto-Schott-Str. 2
D-47906 Kempen
Telephone: +49 (0) 2152 146-0
Fax:

+49 (0) 2152 146-190

E-Mail:

[email protected]

Internet:

http://www.richter-ct.com

Authorised person acc. to machinery directive
2006/42/EG: Gregor Kleining

Designation :

Single-stage, plastic-lined, magnetic drive chemical
centrifugal pump, series MNK, long life grease and oil
bath lubrication
Heavy-duty horizontal design, sealless, free of eddy
currents
Technical specifications to ISO 15783 and DIN ISO
5199
Connecting dimensions to ISO 2858 / DIN EN 22858
Flange connecting dimensions:
DIN EN 1092-2, type B (ISO 7005-2, type B) PN 16
or flanges drilled to ASME 16.5, Class 150
ATEX 95 Directive 94/9/EC
Machine Directive 2006/42/EC

Materials :

Pressure-bearing parts :
ductile cast iron EN-JS 1049 to DIN EN 1563 (0.7043
DIN 1693), carbon fibre composite material

Wetted parts :
PFA, PTFE, PE-UHMW, PP, PFA-P, anti-static lining
(PFA/PTFE conductive) SSiC, FKM/FFKM
see also data sheet.

Flow rate :

up to 300 m

3

/h (bei 2900 min

-1

)

Delivery head :

up to 110 m LC

(bei 2900 min

-1

)

Housing discharge pressure :

max. 16 bar

detailed data see operational limits

Temperature range :

- 60 °C to + 180 °C

Note:

Consult the manufacturer for higher pressures
and lower or higher temperatures.

Noise capacity level :

L

WA

= M 70 dB acc. to

DIN EN ISO 9614-2

Temperature classes :

see Section 2.6.7

Admissible ambient conditions for pumps
acc. to directive 94/9/ EG (ATEX 95) :

Ambient temperature range: - 20 °C to + 40 °C
(higher temperature after consulting the manufacturer)
Ambient pressure range: 0,8 bar

abs

to 1,1 bar

abs

Weight :

See data sheet

Dimensions :

See installation drawing

Advertising