6 fill bearing pedestal with oil, 9 tests, Fill bearing pedestal with oil – Richter MNK Series User Manual

Page 20: Tests, Series mnk

Advertising
background image

Series MNK

Page 20

9230-050-en

Revision 11

TM 7903

Edition 07/2010

7.8.6 Fill bearing pedestal with oil

Oil quantities:

For group 1.1 appr. 220 ml
For group 1.2 appr. 220 ml
For group 1.3 appr. 240 ml
For group 2

appr. 350 ml

Groups see

Section 1

.

See

Section 7.2.2

for the type of oil.

Fig. 7

Procedure for filling with oil:

Tilt constant level oiler

638/1

.

Fill the oiler with oil.
Swing the constant level oiler into the vertical
position.
If the oil level still falls too much, pour more oil into
the oiler.

7.9 Tests

The pumps are tested with water at the
manufacturer's.
The operating data measured are documented in a

works certificate

.

If, during a test after repairs, discrepancies compared
with the works certificate are discovered, the
following people can be called in:
1) in-house pump office
2) The manufacturer Richter

or its local agent

The following conveying data can be checked using
the

pump performance curves

:

Flow rate
Head
Power requirement
NPSHR

Advertising