Plug the power cord into the outlet on the the side of the

mount to turn on the power (Fig.e).

You will find a latitude scale near the top of the fork arm.

Using the directional keys, adjust the telescope tube until the

latitude scale reads 0. (Fig.f).

Next, the telescope must be pointing North from the location

you are using (Fig.g).

After the above is accomplished, the telescope is now

properly setup in the "Home" position.

Turn off the power and turn it back on again.

P

owering the telescope

AUTOTRACKING TELESCOPES

The Auto-tracking Mount power requirement is 12-Volts DC

Nominal. The maximum voltage should not exceed 16-volts and

the minimum is 8-volts. The provided battery pack can hold eight

(8) AA alkaline batteries. It can be place in the tray on the tripod.
MULTIFUNCTION TELESCOPES

The Multi-Function Mount power requirement is 12-Volts DC

Nominal. The maximum voltage should not exceed 16-volts and

the minimum is 8-volts. The battery compartment holds eight (8)

AA alkaline batteries (user supplied). Open the battery

compartment by pressing down on the lever located in the front

of the fork arm base (Fig.d). Remove the battery holders inside

to install or replace batteries.

S

Plug the cable (connector) from the Hand Control into the

telephone type jack at the side of the arm (Fig.e).

Fig.d

Fig.e

Fig.g

Fig.f

GUIDE

SET

GO

SLOW

FAST

1

2

3

4

6

5

7

CRUISE

TRAC

SET LAT

to power

supply

NORTH

etting up the telescope

1.

2.

3.

4.

5.

20

10

0

30

40

50

FOR ASTRONOMICAL USE

AUTOTRACKING TELESCOPES

MULTIFUNCTION TELESCOPES

You will find a latitude scale with two index pointers near

the top of the fork arm. If you are using a camera or a

telescope mounted on the Mounting Platform, use the

pointer on top as reference. If your telescope is mounted

directly on a dovetail bar, use the lower point as reference.

Manually adjust the telescope tube until the latitude scale

reads 0 (Fig.h).

Next, the telescope must be pointing North from the

location you are using.

After the above is accomplished, the Multi-Function Mount

is now properly setup in the "Home" position.

Turn on the power.

Plug the cable (connector) from the Hand Control into the

telephone type jack marked HC at the side of the arm.

1.

2.

3.

4.

5.

Fig.h

0

10

20

30

40

50

60

70

80

90

For telescope on the Mounting

Platform or camera

For telescope with

a dovetail bar