Notes:
• It is recommended to use a high-power telescope and a reticle eyepiece for the PEC train-

ing. A digital eyepiece with a computer is preferred.

• For the equatorial mounts that support PPEC (such as the AZ-EQ6 GT and EQ8 mounts),

an autoguider can be used to replace manual guiding in PEC training process. In such

cases, it is recommended to turn on the autoguiding for at least one minute before starting

the PEC training process. The total time for the PEC training of these mount can be as long

as two cycles of the period error.

Once PEC training is completed, access the menu “

Setup\Tracking\PEC+Sidereal

” and press

the

ENTER

key to start the PEC replay, that is, start to compensate the period error. Choosing

other items in the menu “

Setup\Tracking

” will turn off the PEC.

PEC Replay

11.5 Periodic Error Correction (PEC) for EQ Mount

1.

Polar align the equatorial mount accurately, and then perform a star alignment.

2.

Choose a star close to the celestial equator, point the telescope towards it and start the

mount tracking. Center the star in the telescope’s eyepiece.

3.

Access the menu “

UTILITY FUNCTION\PEC Training

” and press the

ENTER

key, the screen

will display “

Select Speed: 1)0.125X 2)0.25X

”. This is the speed used to adjust the po-

sition of the star in the FOV of the telescope when a user presses the

Left

or

Right

direc-

tion key on the SynScan hand control. Choosing a 0.125X sidereal rate is recommended

for a smaller FOV of telescope, and a 0.25X sidereal rate is recommended for a wider

FOV of telescope. Press the “

1

” or “

2

” key to make a selection and proceed to the next

step.

4.

The screen will display the elapsed time. Use the

Left

and

Right

direction keys to con-

trol the mount and keep the star at the same spot in the FOV of the telescope until the

SynScan hand control stops displaying the time. The total time for this training process

depends on mount models.

The periodic error correction function applies to an equatorial mount only.
All equatorial mount has periodic tracking error which is not critical for visual observing but

might lower the picture quality of long exposure astrophotography. The SynScan hand con-

trol has the periodic error correction (PEC) function to improve the tracking performance for

astrophotography.
Depending on the model of the equatorial mount, there are two types of PEC. One is soft-

ware based PEC (SPEC), which applies to Sky-Watcher’s EQ3/EQ5/HEQ5/EQ6 Pro mount.

The other is permanent PEC (PPEC), which applies to Sky-Watcher’s AZ-EQ6 GT mount and

EQ8 mount. The SynScan hand control can detect the mount model and choose the corre-

sponding PEC algorithm.
The PEC function is a training-replay process.

PEC Training:

PART XI : ADVANCED FUNCTIONS

11.6 Calibrating Auto-Home Offset

• Press “

1

” key to keep the original Home Position Offset.

• Press “

2

” to use the results obtained from the 1-star alignment to calibrate the home

position offset.

1.

PEC can only compensate tracking errors on the R.A. axis. Therefore, a precise polar

alignment is still required to track minor errors on the Dec. axis.

2.

After turning on the PEC replay, it is recommended to wait for at least one cycle time
of the period error before taking a picture.

3.

To re-use the PEC data on a mount which supports SPEC, users should park the tele-

scope before shutting off power

(refer to Section 11.1)

. This limitation does not apply to

the mounts which support PPEC.

Some Sky-Watcher’s equatorial mounts (ex. the EQ 8 mount) has the Auto-Home function

which can set the mount to a standard home position after turning on the power.
The offset of the home position can be calibrated and compensated with the following

procedures:

1.

Polar-align the equatorial mount accurately.

2.

Turn off the power, and then turn it on again, and then initialize the hand control.

3.

When SynScan hand control asks “

Auto-Home?

”, press the “

1

” key to execute the au-

to-home process.

4.

Finish the subsequent initialization steps.

5.

At the end of the initialization, choose 1-star alignment to align the mount.

6.

At the end of the 1-star alignment, the hand control will ask “

Update H.P.O? 1)No 2) Yes