No object found in this region, Enter, Select region – Sky-Watcher Synscan Hand Control User Manual

Page 7: Point scope to rr zz.z’ tt.t, Ctr. to eyepiece, Choose 2, Star, Choose 1, Align- ment successful, Mount stopped. press any key

Advertising
background image

12

13

PART III : ALIGNMENT

3.

The hand control will generate a list of the bright stars within the selected horizontal region.

The list is sorted by the brightness of the star and with the brightest stars at the top of the

list. Users can use the scroll keys to browse the list. An example of the screen display is

shown in

Fig. 3.4b.

• Only stars brighter than magnitude 1.5 will appear in the list. If there is no star brighter

than magnitude 1.5 in the selected region, the hand control will display “

No object found

in this region

.”

• If multiple bright stars appear in the list, users can identify the names of the stars in

the real sky by matching the azimuth, altitude and magnitude provided by the SynScan

hand control.

• Pick one of the star(s) (Generally the brightest one) as the 1

st

alignment star and press

ENTER

key to proceed to the next step. Press the

ESC

key to return to the previous step

(“

Select Region

”).

Fig. 3.4a

Fig. 3.4b

NORTH

EA

ST

S

K

Y

S

O

U

TH

EA

ST S

KY

SO

UTH

WE

ST

S

K

Y

N

O

R

TH

W

ES

T S

KY

NO

RTHERN SKY

E

A

S

T

E

R

N

S

K

Y

SOU

TH

ER

N S

KY

W

E

S

T

E

R

N

S

K

Y

N (0˚)

E (90˚)

S (180˚)

(225˚)

W (270˚)

(315˚)

(135˚)

(45˚)

4.

Now the screen will display “

Point scope to RR ZZ.Z’ TT.T’

”, which means point the telescope

to RR region, the exact azimuth is ZZ.Z degree and the exact altitude is TT.T degree. Users

can use the direction keys on the SynScan hand control to move the mount and point the

telescope to the 1

st

alignment star selected in the previous step. Center the 1

st

alignment

star in the FOV of the finder scope or the red dot finder, and then press

ENTER

key to pro-

ceed to the next step.

PART III : ALIGNMENT

5.

Now the screen will display “

Ctr. to eyepiece..

” and the name of the selected 1

st

alignment

star. The star should have been in the FOV of the telescope. User can use the direction

keys to center it in the eyepiece and then press the

ENTER

key to proceed to the next step.

Aligning the 2

nd

Star:

Cancellation During Aligning Process:

1.

If the 1

st

alignment star is not a planet, the LCD screen will display “

Choose 2

nd

Star

”; other-

wise, it will display “

Choose 1

st

Star

”.

2.

Use the scrolling keys to browse through a list of star names and press

ENTER

key to pick

the one on the screen as the 2

nd

alignment star. The mount will then automatically slew and

point the telescope towards the 2

nd

alignment star in the sky.

3.

After the mount stops, the hand control will display the name of the selected 1st star on line
1 and “Ctr. to eyepiece..“ on line 2. Now the telescope should point rather closely to the 2

nd

alignment star (generally, in the FOV of the finder scope).

4.

Now users can use the direction keys to move the telescope to align with the 2

nd

alignment

star. That is, center the 2

nd

alignment star in the FOV of the finder scope, and then center

it in the FOV of the telescope’s eyepiece. Press

ENTER

key to confirm the centering of the

star and proceed to the next step. Generally, users can use Rate 5 or 6 to center the star

in finder scope and use Rate 2 or 3 to center the star in the telescope’s eyepiece.

5.

If the 1

st

alignment star is not a planet, the SynScan hand control will now display “

Align-

ment Successful

”. Press

ENTER

to complete the alignment process.

6.

If the 1

st

alignment star is a planet, the SynScan hand control will display “

Choose 2

nd

Star

”.

Repeat from Step 2 to complete the alignment process.

1.

While the mount is slewing in alignment process, users may press the

ESC

key to stop the

mount. The hand control screen will display “

MOUNT STOPPED. Press any key…

2.

Press any key and the SynScan hand control will ask the user to select another alignment

star.

3.

Press the

ESC

key again; the LCD screen will display “

Exit Alignment? 1) YES 2) NO

”. Press

key

1

to exit the alignment process; press key

2

to go back to choose an alignment star.

If the telescope has clutches on its axes, user can loosen the clutches to move the mount

manually to point the telescope to the target.

1. Capella

NE 35.3

15.7

Altitude Angle

Star Name

Azimuth Angle

Orientation

Brightness Order

Advertising