Ab b, Sync hr onization & t imecode, Sdi/hdmi – Sound Devices PIX 250i User Manual

Page 45: Sdi/hdmi wordclock

Advertising
background image

PIX 250i User Guide

39

Sync

hr

onization & T

imecode

Camera #1 to PIX #1, Camera #2 to PIX #2, No Genlock

SDI/HDMI

SDI/HDMI

A

A

B

B

In this scenario, each camera is its own master video sync source , but the PIX 250i is the source of

the timecode. The PIX 250i records its files based on the camera’s clock. The heads will match per-

fectly, but the tails may drift depending on the cameras’ clocks.

Camera to PIX with Wordclock Connection to Audio Recorder

SDI/HDMI

Wordclock

1

2

3

4

5

6

7

8

788T

A
B

C
D
E
F

BFS

d

0

IN CF EX

ARM

ARM

BFS

d

0

INPUT

PWR

MENU

HDD

REC

R

L

The wordclock output on the PIX 250i is synchronous with incoming video signal. The wordclock

output can be used to sync external audio recorders to any camera. To enable wordclock output, set

Setup Menu item [Timecode/Sync - Sync Out] to Wordclock, Follows Video In.

Advertising