Timecode/sync, Se tup menu op tions – Sound Devices PIX 250i User Manual

Page 71

Advertising
background image

PIX 250i User Guide

65

Se

tup Menu Op

tions

Timecode/Sync

#

Parameter Name

Description

Options

1

Sync Ref - Video Playback

The reference for synchronization of playback clock.

• Internal
• Video Ref (Sync In)

» Video Input (SDI/HDMI)

2

Timecode Mode

Sets the running mode for the internal timecode gen-

erator and/or the method which the PIX 250i receives

SMPTE timecode..

• Off
• Freerun
• Freerun Auto Mute
• Record Run
• 24h Run
• 24h Run Auto Mute
• Ext TC (LTC)
• Ext TC (LTC Halt)

» Ext TC (SDI, HDMI)

3

Drop Frame Enable

Enable or disable drop frame timecode.

» Off
• On

4

Sync Out

Determines whether the signal on the Sync Output

BNC is genlock or wordclock, and determines the

sync reference for that signal. When settings of a

resolution / frame rate are selected, the Sync Out

BNC will supply genlock signal at the specified rate

that reference the internal Ambient® Lockit.

» Off
• 1080p30
• 1080p29.97
• 1080p25
• 1080p24
• 1080p23.976
• 1080i60/PsF30
• 1080i59.94/PsF29.97
• 1080i50/PsF25
• 1080PsF24
• 1080PsF23.976
• 720p60
• 720p59.94 (29.97)
• 720p50
• 720p30
• 720p29.97
• 720p25
• 720p24
• 720p23.976
• 576i50 (PAL)
• 480i59.94 (29.97 NTSC)
• Genlock, Follows Video In
• Wordclock, Follows Video In

5

Auto-Record Hold Off

Sets the duration that a valid timecode sig-

nal has to be recognized by the PIX 250i

before generating a new take when using ex-

ternal timecode to trigger recording (When

[Remote Control - Rec Start/Stop] is set to

Timecode.

» 0 sec
(numeric 0-8)

6

Jam Received TC

Opens a dialog that displays incoming timecode

value in realtime (RxTC), incoming userbits (UB),

transmitting/internal (Ambient® Lockit) timecode value

(GENTC), and transmitting/internal userbits (UB).

• Push Control Knob to jam inter-

nal timecode to incoming (RxTC)

timecode.
• Push MENU to back out.

7

Jam time Of Day

Sets the internal timecode clock to the current time

of day.

8

Set Generator TC

Sets the Ambient® Lockit timecode generator value in

HH:MM:SS.FF format.

» 00:00:00.00
(Timecode value)

Advertising