Meter ballistics – Sound Devices 722 User Manual

Page 28

Advertising
background image

722 User Guide and Technical Information

26

v. 2.67

Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.

The meter uses energy efficient LEDs viewable in full sunlight. The 722 output meter is unaffected

by shock or extremes in temperature and humidity. Meter ballistics are setup menu selectable among

VU, Peak, Peak-Hold, VU + Peak and VU + PeakHold.

The meter uses a compound metering scale which increases meter resolution in the most important

part of the scale. From

-

50 to

-

40 dBFS, each LED segment equals approximately 10 dB. From

-

40 to

-

12 dBFS, each segment equals 2 dB. From

-

12 to 0 dBFS each segment equals 4 dB.

Meter Ballistics

The output meter can be set to display any of five types of meter ballistics: VU, Peak, Peak-hold,

a combination of VU and Peak, and a combination of VU with Peak-hold. The meter ballistics are

selected in the setup menu.

VU - (Volume Units)

Ballistics correspond closely to how the human ear perceives loudness and provides a good visual

indication of how loud a signal will be. In VU mode, the attack and decay of the meter signal is

300 mS. While giving a very good visual indication of perceived loudness, VU meters gives poor

information on actual signal peaks and are virtually useless for tracking to the 722. In VU mode, the

front panel meter labeling is in volume units.

Peak

Peak-reading ballistics correspond to actual signal maximums, but don’t necessarily correspond to

perceived signal loudness. A peak meter has a near-instantaneous attack to display maximum signal

amplitude and a slow decay to allow the user to see them. Peak metering is essential for digital re-

cording, since signal overload can cause immediate distortion. The peak meters front panel markings

are calibrated in dBFS, decibels relative to full-scale digital signal.

Peak Hold

Essentially the same as Peak metering where the peak level indication will hold for the peak level

indication for several seconds. Peak-hold indicators are useful for metering in applications when an

overload condition is unacceptable.

Peak/VU

The meter can simultaneously display VU and Peak level information. In this mode the perceived

loudness (VU) is displayed on a bar graph, and the Peak signal on a dot above the VU. With this

combination the user gets the best of both VU and Peak metering by seeing both the “loudness” of

the signal and the peaks at the same time. Peak/VU is the factory default.

Peak Hold/VU

Similar to VU/Peak mode, this mode holds the peak level indication for several seconds before

releasing. Peak Hold indicators are useful for metering in applications when an overload condition is

unacceptable.