Model 110r maintenance schedule – Trebor 110R User Manual

Page 10

Advertising
background image

PAGE 10

MODEL 110R PUMP OPERATION / MAINTENANCE MANUAL

MODEL 110R Maintenance Schedule

Normal Operating Conditions

In

stall

30 Days

3 Months

6 Months

9 Months

12 Months

15 Months

18 Mon

ths

21 Months

24 Months

Tie Bolt Torque (32 lb-in)

I

I

I*

I

I*

I

I*

I

I*

I

Detent (<60 CPM)

I

Shuttle Spool and Detent (>60 CPM)

R

Check Balls and O-Rings

R

Shaft Seal and Shaft

R

Diaphragms and Main Seals

R

I=Inspect, R=Replace

Normal operating conditions are those not described in the Extreme Operating Conditions below
*Required if operating temperature exceeds 60°C or thermal cycling occurs

Extreme Operating Conditions*

In

stall

30 Days

3 Months

6

Months

9 Months

12 Months

15 Months

18 Months

21 Months

24 Months

Tie Bolt Torque (32 lb-in)

I

I

I**

I

I**

I

I**

I

I**

I

Detent (<60 CPM)

I

Shuttle Spool and Detent (>60 CPM)

R

Check Balls and O-Rings

R***

R

R***

R

Shaft Seal and Shaft

R***

R

R***

R

Diaphragms and Main Seals

R***

R

R***

R

I=Inspect, R=Replace

*Extreme operating conditions are applications requiring high suction or the fluid is HF, ACT 935, or TMAH
(strong etchants)
**Required if operating temperature exceeds 60°C or thermal cycling occurs
***Required if fluid is ACT 935 or TMAH