5 parts list, 6 clean-up, 7 disassembly – Trebor 110R User Manual

Page 14

Advertising
background image

PAGE 14

MODEL 110R PUMP OPERATION / MAINTENANCE MANUAL

4.5 PARTS LIST

ILL
NO

PART NO

QTY

DESCRIPTION

PM

YEAR #

MATERIAL

1

J0092

1

Body

PTFE

2

1110B0012

2

Suction Sleeve

PTFE

3

98002318

4

O-Ring, PTFE Check Valve

2

PTFE

4

J0097

4

Check Ball

2

PFA

5

1110B0013

2

Discharge Sleeve

PTFE

6

J0100

2

Seal, Check Bore Cap

2

PTFE

7

J0101

2

Check Bore Cap

PTFE

8

98001167

2

Shaft Seal

2

PTFE

9

1110A0035

1

Shaft

2

PFA

10

J0093

2

Push Plate

PTFE

11

J0090

2

Diaphragm Set

2

PFA

12

98001423

2

Main Seal

2

Viton

13

1110B0015

6

Tie Bolt Assembly

SS416, PFA

14

1110D0011-01

1

Slave Head

PP

15

11001220

2

Pilot Valve

Brass, SS,

NBR

16

1110A0022

2

Main Transfer Tube

PFA

17

98002332

2

O-Ring, Transfer Tube

2

Viton

18

1110A0023

1

Pilot Transfer Tube

PFA

19

98002331

2

O-Ring, Transfer Tube

2

Viton

20

AM022

1

Mounting Base

PP

21

98003207

4

Mounting Screw

PP

22

98003071

1

Locking Lever Screw

PP

23

AM023

1

Locking Lever

PP

24

C0102

1

Quick Release Base

PP

25

1100C0026

1

Shuttle Plug

PP

26

11001230

1

Detent

1 & 2

Acetal, SS

27

11001210

1

Shuttle Assembly

1 & 2

SS410, Buna

28

C0135

1

Check Muffler Assembly

2

PP, NPRN

29

98001109

12

Tie Bolt Cap

2

PU

30

98002338

6

Nut, Flanged

SS18-8

31

1110D0010-01

1

Master Head

PP

4.6 CLEAN-UP

The pump fluid cavities may be flushed clean by cycling with the suction (IN) and
discharge (OUT) lines connected to a DI water flushing or rinsing tank. Flushing
using an external pressure source without allowing the pump to cycle will result in
incomplete removal of potentially dangerous chemicals.

NOTE: To effectively eliminate chemical contamination, the pump should cycle
for 10-15 minutes using the flushing DI water as described above.

4.7 DISASSEMBLY

During the life of the pump it will be necessary to perform certain preventative
maintenance procedures to ensure continued high performance operation. This
section and the next (4.8

Assembly) are provided for the user’s convenience in

disassembly and re-assembly procedures.

Thoroughly clean / flush the pump using DI water (Refer to Section 4.6

Clean-Up).

Unlock pump from quick release base by pulling out locking lever on front of

base. Then slide pump forward until it stops. Lift pump off base.

Remove check muffler assembly.

Advertising