8 assembly – Trebor 110R User Manual

Page 16

Advertising
background image

PAGE 16

MODEL 110R PUMP OPERATION / MAINTENANCE MANUAL

4.8 ASSEMBLY

4.8.a Head Assemblies

Pilot Valve (Both Heads)

Install the pilot valves with 2 wraps of TFE thread tape in each head.

Figure 4-1

Shuttle Assembly (Master Head)

NOTE: Ensure that the shuttle spool moves freely inside the shuttle sleeve prior
to installation. Never lubricate spool or sleeve.

Check the shuttle assembly making sure it has notched O-rings on each end.

(See Section 4.4 for shuttle detail.)

Insert shuttle sleeve into the shuttle bore.

Insert shuttle spool.

Insert detent.

Install shuttle cap with 2 wraps of TFE tape.