5troubleshooting – Trebor PC15CP User Manual

Page 11

Advertising
background image

PC15CP PUMP CONTROLLER OPERATION / MAINTENANCE MANUAL

PAGE 11

5

TROUBLESHOOTING

SYMPTOMS

SOLUTIONS

Pump turns on when on/off switch is

activated, but the pump is running slow

Increase cycle rate setting: maximum of

375.

Pump flow does not increase with cycle

rate

Confirm regulated air supply pressure at

50-80 psig.

Increase pump discharge pressures if

discharge pressure is not surging!

Reduce inlet suction (Lift) requirements.

Pump is surging (discharge pressure

variation >4 psig)

Initiate controller calibration to reduce

pulsation. Contact Trebor

Reduce inlet suction requirements.

Increase cycle rate.

Controller display does not turn on

Check power supply voltage >19VDC.

Pump will not run

Check pump regulator pressure is above

15 psig.

Check controller air supply pressure <>

50-80 psig.

Check if remote operation enabled.

Pump will not prime

Increase cycle rate.

Check controller supply pressure is >50

PSIG.

Advertising