Permanent installation, Where to install – Tundra HTS3000(T) User Manual

Page 18

Advertising
background image

HTS(T)-1800_3000-GD-0114-EN

6


OVR LOAD
Indicates the inverter has reached its maximum
output capacity (Wattage) and must shutdown.
This is likely to happen when the total
consumption (Wattage) is too high for the model
you chose. Once the consumption will back down
within the operation limits of your model, the
inverter will resume automatically.

3

PERMANENT INSTALLATION


The use of the Tundra International CM SERIES installation kits is strongly recommended.
These complete installation kits are custom designed to maximize the performances of our inverters and to
promote the safest possible installation. It also helps eliminate the difficult task of sourcing the right material
and to cut down on installation costs and time.


MAKE SURE TO USE THE RIGHT INSTALLATION KIT – YOU MAY REFER TO THE HEREAFTER
SECTION OF OUR WEBSITE TO SELECT THE RIGHT KIT FOR YOUR INVERTER AND YOUR
APPLICATION
:

http://www.tundrainternational.com/en/pages/cmseries


* MORE THAN 30 MODELS ARE AVAILABLE

CM SERIES installation kit content

- High quality cables - 6 to 12ft./pole (1.83 to 3.7m./pole) depending on the chosen kit
- Tin plated terminal lugs - crimped and color coded from factory
- 2 PVC strain reliefs - to safely run the cables through sheet metal floors
- Fuse kit - 1 CNL fuse rated for the chosen inverter and 1 holder
- Plastic “loom” tubing - to protect the cables from road hazards and other possible wear
- High endurance plastic cable ties - to secure the cables from one end to the other
- Hardware kit - includes all the required metal clamps and screws

Recommended tools
- Hole saw for metal

- Drill bit set for metal

- Screw driver set

- Open end wrench set

- Side cutters

- Power drill


CAUTION!

Before installation, make sure that the inverter is turned “OFF.”

3.1

Where to install

Your inverter should be installed in a location that meets the following requirements:

- Safe

Power inverters may produce sparks that can result in fire if exposed to flammable vapors.
Find a location away from any kind of flammable liquids or flammable material. Never
install the inverter in the same compartment as the batteries.

- Safe

A malfunction or accidental liquid spill may result in severe injuries or death. Always
install the inverter in an isolated compartment, away from direct contact with persons.

Advertising