Troubleshooting

Problem

Possible cause

Solution

Fault codes and Alarms
(alarm ON + inverter OFF)

ERR LOW = Low input voltage
(Yellow LED flashing &
steady alarm)





ERR HIGH = High input voltage
(Yellow LED flashing &
steady alarm)


OVR LOAD = Overload
(Yellow LED flashing &
steady alarm)








OVER TEMP
(Yellow LED flashing &
steady alarm)





Discharged batteries

Insufficient battery capacity

Improper installation



Input voltage is higher than
15V.



Total consumption exceeds
the inverter’s nominal
capacity

A short circuit / damages AC
cord (120V)

Defective appliances




Thermal shutdown



Improper installation




Recharge batteries

Add batteries

Go through inverter’s installation
steps / Section 3 above


Check vehicle alternator’s
condition



Remove or reduce loads, switch
the inverter OFF at least 5 second
and restart the inverter

Check the AC wiring (120 Volt)


Test your appliance on another
power source to validate its good
functioning


Allow inverter to cool off

Improve ventilation

Install according to
recommendations / Section 3

Fault codes and alarms
(alarm ON + inverter ON)

Battery symbol flashing
(Green LED flashing &
intermittent alarm)




Discharged batteries

Poor battery condition

Poor DC connections



Recharge batteries

Replace batteries

Clean all connections related to
battery cables and DC fuse.
Reduce the loads