INSTALLATION PROCEDURES

12

Manual 0-2023

3. Connect plug (supplied) to the end of the input power

cord per the following:

a. Feed the free end of the input power cable through

the small section of the rubber plug housing.

b. Connect the ground lead to the green terminal on

the plug.

c. Connect the other two leads to the two terminals

on the plug.

d. Press the plug into the rubber housing until the

plastic disk is captured by the rubber housing.

e. Tighten cord grip to secure input cable.

B. Cable Connections

1. Connect RP1 Control pendant to the connector on the

end of the 20 foot (6.1 m) Remote Control Cable. Con-
nect the other end of the cable to the back of the Weld
Sequencer Enclosure marked REMOTE CONTROL.

REMOTE

CONTROL

CONSOLE/POWER SUPPLY

CONTROL

A-02406

Control Cable

Console/Power Supply

Control Cable

Figure 3-3 Weld Sequencer Enclosure Rear Panel

Connections

If a different remote control device is to used refer to
the Wiring Diagram supplied with the Weld Se-
quencer. The current control potentiometer must be
rated for 10k ohm at 2 watts.

Plasma Gas

Shield Gas

A-02407

Weld
Sequencer

Optional Remote

Control

Torch

Welding

Console

DC Power

Supply

Coolant Recirculator

Figure 3-4 WC100B Connections