C. cp1 current pulser – Tweco Weld Sequencer User Manual

Page 31

Advertising
background image

Manual 0-2023

25

OPERATION

D ow n s l o p e S i g n a l

I n i t i a t e d

D ow n s l o p e D e l ay

( 0 - 1 0 s e c )

A - 0 2 4 3 1

C. CP1 Current Pulser

1. Move ON/OFF switch to the ON position.

2. Adjust the PULSE RATE control knob to set desired

pulses per second (clockwise rotation increases pulse
rate).

A - 0 2 4 3 2

O n e P u l s e

O n e P u l s e

3. Determine the relationship required of peak current

on time versus background current on-time in per-
cent. Set the PERCENT ON TIME knob to the appro-
priate number (1 = 10%, 5 = 50%, etc).

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

50%

Background ON

50%

Peak ON

75%

Peak ON

A-02433

25%

Background ON

NOTE

When sloping the pulse, PERCENT ON TIME of
peak current is not proportional to background
current on-time.

I n i t i a l a n d F i n a l C u r r e n t C o n t r o l S e t t i n g s

v s. S l o p e T i m e Fo r D i f fe r e n t S l o p e R a t e s

( S a m e U p s l o p e a n d D ow n s l o p e )

S l o p e T i m e ( s e c o n d s )

Initial or Final Current Control Setting

0 5 1 0 1 5 2 0 2 5 3 0 3 5

1 0

9

8

7

6

5

4

3

2

1

0

Rate = 10

Rate = 9

Rate = 8

Rate = 7 Rate = 6 Rate = 5 Rate = 4Rate = 3Rate = 2Rate = 1

Rate = 0

A - 0 2 4 3 0

Figure 4-8 Upslope and Downslope Rates for Initial or Final Current Settings and Slope Times

Advertising