ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-6

INSTALLATION

Manual 0-5264

3.08 Connect Input Power and Ground Cables

Connect Input Power and System Ground Cables

1. Remove the input power cover to the right of the coolant filter at the rear of the power supply. To do this

remove the two screws then lift up and pull away.

2. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut

back the insulation on the individual wires. Route the cable upward through Input Power Port at the bottom

of the panel. There are 2 extra plates included at the cable entrance. Discarding one or both allows changing

the opening size for larger cable/strain relief.

3. Install stripped end of 3 phase wires into the terminal block L1, L2 and L3 and connect the individual cables

as shown.

4. Connect the power cable ground wire to the ground terminal block.

5. Route a system ground cable (F1) through the last opening in the connections cover support panel next to

the input power cable. Connect the cable to the ground terminal block on the power supply rear panel.

Refer to the Ground Connections Section for full details and procedures on proper system grounding.

Ground

Ground Terminals