Technical data, Reverse osmosis, Ro-m – Unger RO60S User Manual

Page 21: Scope of delivery

Advertising
background image

www.ungerglobal.com

21

ENGLISH

1

1

2

2

3

3

3

4

4

5

6

8

8

9

9

10

10

12

12

7

7

11

13

5

6

13

11

RO30G

RO60S

RO30C

H

i

F

lo

™ Ro-M

obile

Technical Data

H

i

F

lo

™ Ro-M

obile

Reverse osmosis

3. Technical Data

3.1. Scope of delivery

RO30G & C

RO60S

Electrical connection, primary

230 V/50 Hz

Inlet pressure

0-6 bar

Max. operating pressure

10 bar

Suction capacity (with 1“ line, 15°C)

5m/-0,5 bar

Yield

ca. 60 %

Water temperature

5°C-25°C

Required power

at 15°C

Salinity in raw water

max. 1000 mg/l

Salt retention rate

100% (resin filter)

Blocking index

max. 3

SiO2 content in raw water

20 mg/l

Permeate output at 15°C water temperature l/h

300-350l

650-710l

Pump connection

0,75 kW

1,1 kW

Standard feed water connection

G3/4“

1“

Standard concentrate connection

G3/4“

Standard permeate connection

G3/4“

Height

1230 mm

1230 mm

Width

580 mm

750 mm

Depth

510 mm

510 mm

Weight

app. kg 55 app.. 73 kg

1. Robust trolleyl
2. Water supply connection
3. RO30G: 2,5“x 10“ Standard-Pre-filter

RO30C: 4,5“ x 10“ Carbon-Pre-filter (Chlorine)
RO60S: 4,5“ x 10“ Standard-Pre-filter

4.

Pressure gauge water inlet downstream pre-filter

5. RO30G&C: Main membrane

RO60S: Doublemembrane

6.

RO30G & C: 4,5“ x 20“ Secondary resin filter
RO60S: 4,5“ x 20“ Carbon-Pre-filter (Chlorine)

7. Concentrate outlet
8. Pump control system
9. Permeate outlet
10. Pump
11. TDS-meter
12. Pressure indicator, pump
13. Pressure relief valve

Filter wrench, pre-filter (small)

Filter wrench, pre-filter (large)

Feed pipe for preservation