Parts overview / function plan

H

i

F

lo

™ Ro-M

obile

Preservation

6.1. Switching system off

Cut off the water supply (2) and wait until the system switches off.

Now cut off the water at the water line and remove the hose.

Remove the system from the power supply.

Now close the water outlet (9) and pull the hose off the pole.

Now open both water connections (2) & (9) again in order to depressurise the
line and allow the rest of the water to run out.

6.2. Maintenance and care

If the system is shut down for a prolonged period (7 days), it must be preserved to
prevent contamination of the membrane.
It is recommended to have the system serviced 1x per year by the authorised dealer or
Unger.

6.2.1. Pre-filter

Prior to each start-up, visually check the degree of contamination of the pre-filter (3)
and replace, if necessary.

6.3. Anti-freeze protection

The system must be protected against frost. Minimum ambient temperature 5°C.

CAUTION

Never use any other chemicals, since all agents used must be
tested for membrane compatibility.