7 back panel – Crown COMTECH DRIVECORE CT 875 User Manual

Page 11

Advertising
background image

CT Power Amplifiers

page 11

CT Power Amplifiers

Operation Manual

7 Back Panel

1. AC Power Inlet

• Standard IEC type 320 inlet for detachable

connector

• 100-240V

2. Reset Button/Breaker

• Push button switch
• Resets the circuit breaker that protects the power

supply

• A circuit breaker located near the IEC power inlet

protects the amplifier from excessive AC current

draw.

3. Auxiliary Connector

• 3-pin Phoenix type connector
• Allows for amp to be placed in DEEP SLEEP

mode and monitoring of AMP STATUS

(see Section 10.2)

4. Amp Configuration DIP Switches (see Amp

Status/Configuration in section 10.2)

• Switches 1-5 turn specific settings on and off:

-70 Hz HPF (High Pass Filter

- see Section 8.1)

-Auto-Standby

-Amp Status

-Green Power (See Section 9.2)

-Limiter

• Switches 6-12 sends input channel audio signal

to corresponding output channel and adjacent

output channel. In four channel model, switch
6-9 are non-functional, (see section 11)

5. Amp Input Connectors

• 3-pin block connector can be used per input
• High impedance balanced

6. Channel Level Controls

• One 21-position detented rotary attenuator per

channel

• Attenuation range from -100dB to 0dB

7. Output Speaker Connector

• 4-pin Barrier block type per two channels

(2-Pin or 8-Pin Phoenix can be used)

1

2

3

4

5

6

7

5

6