17 ac power draw and thermal dissipation, Comtech drivecore 8150 – Crown COMTECH DRIVECORE CT 875 User Manual

Page 20

Advertising
background image

Operation Manual

CT Power Amplifiers

page 20

17 AC Power Draw and Thermal Dissipation

ComTech DriveCore 8150

Load

Watts in

Watts

out

120VAC

Watts

Dissipated

Watts in

Watts out

240VAC

Watts

Dissipated

Thermal Dispation

Line

Current

Watts Out

Per 1A Line

Current

Line

Current

Watts Out

Per 1A Line

Current

btu/hr

kcal/hr

Idle (Deep Sleep)

-

0.9

<0.1

1.00

1.00

<0.1

1

3.41

0.86

Idle (Auto Standby)

-

17

0.35

17.00

15.80

0.28

15.8

57.97

14.60

Idle (Awake)

-

26.5

0.60

26.50

25.00

0.37

25

90.37

22.76

Idle (Green Power)

-

14.5

0.40

-

14

0.30

-

-

-

1/8th Power Pink

Noise

8

179

122

3.40

36

57

185

125

2.10

60

60

204.60

51.54

6

221

155

4.00

39

66

210

150

2.10

71

60

225.06

56.69

4

207

131

3.50

37

76

201

125

2.10

60

76

259.16

65.28

1/3rd Power Pink

Noise

8

438

325

7.60

43

113

445

330

4.30

77

115

392.15

98.79

6

550

400

6.50

62

150

525

321

4.50

71

204

695.64

175.24

4

525

349

5.70

61

176

510

309

4.40

70

201

685.41

172.66

1/8th Power Sine

8

183

125

3.37

37

58

180

125

1.93

65

55

197.78

49.82

6

221

152

4.00

38

68

221

155

2.33

67

66

232.90

58.67

4

205

133

3.74

36

72

198

131

2.12

62

67

245.52

61.85

1/3rd Power Sine

8

452

334

7.85

43

118

436

329

4.36

75

107

402.38

101.36

6

570

413

9.93

42

157

558

413

5.56

74

145

535.37

134.86

4

507

349

8.79

40

158

495

350

4.93

71

145

538.78

135.72

AC Power Draw and Thermal Disspation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.

Typical line impedance used.

Measurements made with 120/240 VAC mains.

Data based on all channels driven at 8 Ohms.

Advertising