17 AC Power Draw and Thermal Dissipation

ComTech DriveCore 875

Load

Watts in

Watts

out

120VAC

Watts

Dissipated

Watts in

Watts out

240VAC

Watts

Dissipated

Thermal Dispation

Line

Current

Watts Out

Per 1A Line

Current

Line

Current

Watts Out

Per 1A Line

Current

btu/hr

kcal/hr

Idle (Deep Sleep)

-

0.9

<0.1

1.00

0.90

<0.1

1

3.41

0.86

Idle (Auto Standby)

-

17

0.40

17.00

15.50

0.25

15.8

57.97

14.60

Idle (Awake)

-

23

0.50

23.00

21.00

0.32

25

85.25

21.48

Idle (Green Power)

-

14.5

0.40

-

14

0.30

-

-

-

1/8th Power Pink

Noise

8

117

75

2.40

31

42

114

75

1.32

57

39

143.22

36.08

6

121

75

2.50

30

46

117

75

1.40

54

42

156.86

39.51

4

126

75

2.60

29

51

122

75

1.60

47

47

173.91

43.81

1/3rd Power Pink

Noise

8

277

200

4.66

43

77

270

200

2.85

70

70

262.57

66.14

6

284

200

4.90

41

84

275

200

2.90

69

75

286.44

72.16

4

292

200

5.30

38

92

283

200

3.00

67

83

313.72

79.03

1/8th Power Sine

8

115

75

2.11

35

40

113

75

1.27

59

38

136.40

34.36

6

116

75

2.14

35

41

114

75

1.28

58

39

139.81

35.22

4

119

75

2.20

34

44

118

75

1.32

57

43

150.04

37.80

1/3rd Power Sine

8

269

200

4.60

43

69

266

200

2.77

72

66

236.31

59.53

6

273

200

4.66

43

73

269

200

2.80

71

69

248.93

62.71

4

283

200

4.82

42

84

279

200

2.90

69

79

285.08

71.81

AC Power Draw and Thermal Disspation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.

Typical line impedance used.

Measurements made with 120/240 VAC mains.

Data based on all channels driven at 8 Ohms.