W A R R A N T Y W I L L B E V O I D

I F I N S T R U C T I O N S A R E N O T F O L L O W E D

INSTALLATION

The installation instructions provide a general guideline for the installation and wiring of the exhaust fan.

All applicable codes must be adhered to.

IMPORTANT NOTICES

1. Read and follow the instructions in this manual.

2. Fan(s) are to be installed and serviced only

by qualified personnel experienced in electrical and

HVAC work.

3. Installation and wiring of the fan must

adhere to all applicable codes.

4. It is essential that any fan, that will be used

in a hazardous (classified) location, is equipped with

an electric motor approved for such service.

5. Do not operate fan in atmospheres which are

corrosive to steel or aluminum, unless it has been

coated with a factory approved protective coating.

6. Fan must be kept clean. When operating in

a dirty environment, regularly clean fan and

fan guard. Follow the recommended

maintenance procedures. Refer to the “Fan

Maintenance Checklist” section for details.

7. Use factory approved replacement parts only.

8. If there are any questions or concerns regarding

the fan, contact the factory. Refer to the last

page of this manual for details.

WARNING:

Read and adhere to the following. Failure to do so may result in severe or fatal injury.

LOCATION

1. For optimum air exhaust, the fan(s) should be

installed as follows:

a. There are no obstructions that may impede

the fans air inlet or discharge.

b. The air discharge is directed away from

building.

c. The air discharge is not directed at a

thermostat.

d. For warehouses or large workshops it may

be acceptable to use fewer, larger fans.

2. This unit can exhaust warm or cool air depending

on customer conditions. Be aware of problems

each can produce.

MOUNTING

1. The Exhaust Fan is designed to be installed in an

upright and level position.

2. Fan(s) are designed to be mounted from the rear

using four 3/8” holes. For fan dimensions,

see Figure 2.

3. The mounting structure must be strong enough to:

a. Support the fans weight

(refer to the specification section).

b. Provide sufficient stiffness to prevent

excessive vibration.

c. Withstand abusive situations such as

transportable installations.

d. If Exhaust Fan is installed on a wall thinner

than 4”, customer will need to install shims to

bring face of fan away from mounting

surface.

- 3 -